TDT, TST actuator (2-stage control is suitable for measuring system line.)
Features
- Fluid
- Air
- Maximum Operating Pressure
- 0.69MPa (7kg/cm2G)
- Permissible Environment Temperature
- -20°C~+80°C
- Lubrication Oil
- No need
- Guaranteed Operation Cycles
- 100,000 cycles
- Rotation Angle
- Half open:0~45 degree
Full open/close:0~90 degree
Features
- The opening ratio (Max. 45 degree) of valve can be adjust at an arbitrary position.
- The operation pressure of actuator supplied from solenoid valve directly not through positioner, therefore the response of open/close can be quickly.
- And it is possible to do fine adjustment by repetitive operation close to half open.(TST model only).
- Spring return cylinder (Model:TST) is possible to use for emergency shut down, at the time of electric power failure and stop the air supply.
ACTION FLOW