TDT, TST actuator (2-stage control is suitable for measuring system line.)

Features

Fluid
Air
Maximum Operating Pressure
0.69MPa (7kg/cm2G)
Permissible Environment Temperature
-20°C~+80°C
Lubrication Oil
No need
Guaranteed Operation Cycles
100,000 cycles
Rotation Angle
Half open:0~45 degree
Full open/close:0~90 degree

Features

  • The opening ratio (Max. 45 degree) of valve can be adjust at an arbitrary position.
  • The operation pressure of actuator supplied from solenoid valve directly not through positioner, therefore the response of open/close can be quickly.
  • And it is possible to do fine adjustment by repetitive operation close to half open.(TST model only).
  • Spring return cylinder (Model:TST) is possible to use for emergency shut down, at the time of electric power failure and stop the air supply.

ACTION FLOW

ACTION FLOW